Search

Top hat furnace - HB

HB__/80

Max temp (°C) 1700, 1800
Volume (l) 80

[read more] [read less]

Uniformity between 800°C and Tmax (°C) [DIN 17052] ± 5
Max. heat-up rate (°C/min) 5, 10, 10, 10
Cooling time (h) 12, 14, 14, 14
Dimensions:
Internal H x W x D (mm)
500 x 400 x 400
Dimensions:
External H x W x D (mm)
2580 x 1245 x 1650
Max power (kW) 18, 45, 50, 60

HB__/160

Max temp (°C) 1700, 1800
Volume (l) 160

[read more] [read less]

Uniformity between 800°C and Tmax (°C) [DIN 17052] ± 5
Max. heat-up rate (°C/min) 5, 10, 10, 10
Cooling time (h) 14, 14, 14, 14
Dimensions:
Internal H x W x D (mm)
500 x 800 x 400
Dimensions:
External H x W x D (mm)
2525 x 1475 x 1650
Max power (kW) 30, 80, 85, 90

HB__/240

Max temp (°C) 1300, 1600, 1700, 1800
Volume (l) 240

[read more] [read less]

Uniformity between 800°C and Tmax (°C) [DIN 17052] --
Max. heat-up rate (°C/min) --
Cooling time (h) 14
Dimensions:
Internal H x W x D (mm)
500 x 1200 x 400
Dimensions:
External H x W x D (mm)
2200 x 2200 x 1200
Max power (kW) --

HB__/430

Max temp (°C) 1300, 1600, 1700, 1800
Volume (l) 430

[read more] [read less]

Uniformity between 800°C and Tmax (°C) [DIN 17052] --
Max. heat-up rate (°C/min) --
Cooling time (h) --
Dimensions:
Internal H x W x D (mm)
600 x 1200 x 600
Dimensions:
External H x W x D (mm)
2500 x 2200 x 1500
Max power (kW) --

HB__/560

Max temp (°C) 1300, 1600, 1700, 1800
Volume (l) 560

[read more] [read less]

Uniformity between 800°C and Tmax (°C) [DIN 17052] --
Max. heat-up rate (°C/min) --
Cooling time (h) --
Dimensions:
Internal H x W x D (mm)
780 x 1200 x 600
Dimensions:
External H x W x D (mm)
2700 x 2200 x 1400
Max power (kW) --

HB-BL__/240

Max temp (°C) 1300, 1600, 1700, 1800
Volume (l) 240

[read more] [read less]

Uniformity between 800°C and Tmax (°C) [DIN 17052] --
Max. heat-up rate (°C/min) --
Cooling time (h) 14
Dimensions:
Internal H x W x D (mm)
500 x 1200 x 400
Dimensions:
External H x W x D (mm)
3600 x 2200 x 2500
Max power (kW) 63, 65, 69, 75

HB-BL__/430

Max temp (°C) 1300, 1600, 1700, 1800
Volume (l) 430

[read more] [read less]

Uniformity between 800°C and Tmax (°C) [DIN 17052] --
Max. heat-up rate (°C/min) --
Cooling time (h) --
Dimensions:
Internal H x W x D (mm)
600 x 1200 x 600
Dimensions:
External H x W x D (mm)
3700 x 2200 x 2700
Max power (kW) --

Please note
- Maximum continuous operating temperature is 100 °C below maximum temperature

Content may be subject to modifications or corrections