RHF 14/3
Max temp (°C) |
1400 |
Volume (litres) |
3 |
[read more]
[read less]
Heat-up time (mins) |
33 |
Dimensions: Internal H x W x D (mm) |
120 x 120 x 205 |
Dimensions: External H x W x D (mm) H (door open) |
655 x 435 x 610 (905) |
Configuration |
Bench-top |
Max power (W) |
4500 |
Holding power (W) |
1900 |
Thermocouple type |
R |
Weight (kg) |
42 |
Power supply required per phase |
Single phase 200-240V 30A, 380-415V 2 phase 15A |
RHF 14/8
Max temp (°C) |
1400 |
Volume (litres) |
8 |
[read more]
[read less]
Heat-up time (mins) |
22 |
Dimensions: Internal H x W x D (mm) |
170 x 170 x 270 |
Dimensions: External H x W x D (mm) H (door open) |
705 x 505 x 675 (990) |
Configuration |
Bench-top |
Max power (W) |
8000 |
Holding power (W) |
3200 |
Thermocouple type |
R |
Weight (kg) |
64 |
Power supply required per phase |
Single phase 200-240V 50A, 380-415V 2 phase + N 25A |
RHF 14/15
Max temp (°C) |
1400 |
Volume (litres) |
15 |
[read more]
[read less]
Heat-up time (mins) |
35 |
Dimensions: Internal H x W x D (mm) |
220 x 220 x 310 |
Dimensions: External H x W x D (mm) H (door open) |
810 x 690 x 780 (1105) |
Configuration |
Bench-top |
Max power (W) |
10000 |
Holding power (W) |
2900 |
Thermocouple type |
R |
Weight (kg) |
125 |
Power supply required per phase |
380-415V 3 phase + N 22A, 200-220V 3 phase delta 38A |
RHF 14/35
Max temp (°C) |
1400 |
Volume (litres) |
35 |
[read more]
[read less]
Heat-up time (mins) |
38 |
Dimensions: Internal H x W x D (mm) |
250 x 300 x 465 |
Dimensions: External H x W x D (mm) H (door open) |
885 x 780 x 945 (1245) |
Configuration |
Bench-top |
Max power (W) |
16000 |
Holding power (W) |
6000 |
Thermocouple type |
R |
Weight (kg) |
179 |
Power supply required per phase |
380-415 3 phase + N 35A, 200-220V 3 phase delta 60A, 440-480V 3 phase no N 35A |
RHF 15/3
Max temp (°C) |
1500 |
Volume (litres) |
3 |
[read more]
[read less]
Heat-up time (mins) |
45 |
Dimensions: Internal H x W x D (mm) |
120 x 120 x 205 |
Dimensions: External H x W x D (mm) H (door open) |
655 x 435 x 610 (905) |
Configuration |
Bench-top |
Max power (W) |
4500 |
Holding power (W) |
2000 |
Thermocouple type |
R |
Weight (kg) |
46 |
Power supply required per phase |
220-240V single phase 36A, 380-415V, 2 phasse + N, 18A |
RHF 15/8
Max temp (°C) |
1500 |
Volume (litres) |
8 |
[read more]
[read less]
Heat-up time (mins) |
40 |
Dimensions: Internal H x W x D (mm) |
170 x 170 x 270 |
Dimensions: External H x W x D (mm) H (door open) |
705 x 505 x 675 (990) |
Configuration |
Bench-top |
Max power (W) |
8000 |
Holding power (W) |
3500 |
Thermocouple type |
R |
Weight (kg) |
61 |
Power supply required per phase |
200-220 3 phase delta 30A, 200-208V 3 phase + delta 38A, 380-415V 3 phase delta 17.5A |
RHF 15/15
Max temp (°C) |
1500 |
Volume (litres) |
15 |
[read more]
[read less]
Heat-up time (mins) |
46 |
Dimensions: Internal H x W x D (mm) |
220 x 220 x 310 |
Dimensions: External H x W x D (mm) H (door open) |
810 x 690 x 780 (1105) |
Configuration |
Bench-top |
Max power (W) |
10000 |
Holding power (W) |
3000 |
Thermocouple type |
R |
Weight (kg) |
125 |
Power supply required per phase |
380-415V 3 phase + N 25A, 230-240V 3 phase delta 43A, |
RHF 15/35
Max temp (°C) |
1500 |
Volume (litres) |
35 |
[read more]
[read less]
Heat-up time (mins) |
46 |
Dimensions: Internal H x W x D (mm) |
250 x 300 x 465 |
Dimensions: External H x W x D (mm) H (door open) |
885 x 780 x 945 (1245) |
Configuration |
Bench-top |
Max power (W) |
16000 |
Holding power (W) |
6200 |
Thermocouple type |
R |
Weight (kg) |
178 |
Power supply required per phase |
380 - 415 3 phase + N 35A, 440-480V 3 phase no N 60A, 380-415V 3 phase no N 35A, 440-480 3 phase + N 35A |
RHF 16/3
Max temp (°C) |
1600 |
Volume (litres) |
3 |
[read more]
[read less]
Heat-up time (mins) |
42 |
Dimensions: Internal H x W x D (mm) |
120 x 120 x 205 |
Dimensions: External H x W x D (mm) H (door open) |
655 x 435 x 610 (905) |
Configuration |
Bench-top |
Max power (W) |
4500 |
Holding power (W) |
2300 |
Thermocouple type |
R |
Weight (kg) |
42 |
Power supply required per phase |
200-240V single phase 36A, 380-415V 2 phase + N 18A, 200-240V 3 phase delta 30A |
RHF 16/8
Max temp (°C) |
1600 |
Volume (litres) |
8 |
[read more]
[read less]
Heat-up time (mins) |
35 |
Dimensions: Internal H x W x D (mm) |
170 x 170 x 270 |
Dimensions: External H x W x D (mm) H (door open) |
705 x 505 x 675 (990) |
Configuration |
Bench-top |
Max power (W) |
8000 |
Holding power (W) |
4000 |
Thermocouple type |
R |
Weight (kg) |
61 |
Power supply required per phase |
380-415V 3 phase + N 18A, 220-240V 3 phase delta 29A, 200-208V 3 phase delta 34A, 380-415V 3 phase no N 18A, 440-480V 3 phase no N 18A |
RHF 16/15
Max temp (°C) |
1600 |
Volume (litres) |
15 |
[read more]
[read less]
Heat-up time (mins) |
58 |
Dimensions: Internal H x W x D (mm) |
220 x 220 x 310 |
Dimensions: External H x W x D (mm) H (door open) |
810 x 690 x 780 (1105) |
Configuration |
Bench-top |
Max power (W) |
10000 |
Holding power (W) |
3500 |
Thermocouple type |
R |
Weight (kg) |
140 |
Power supply required per phase |
380-415V 3 phase + N 25A, 200-240V 3 phase delta 42A, 440-480V 3 phase + N 25A |
RHF 16/35
Max temp (°C) |
1600 |
Volume (litres) |
35 |
[read more]
[read less]
Heat-up time (mins) |
113 |
Dimensions: Internal H x W x D (mm) |
250 x 300 x 465 |
Dimensions: External H x W x D (mm) H (door open) |
1530 x 900 x 1020 (1885) |
Configuration |
Floor-standing |
Max power (W) |
16000 |
Holding power (W) |
7000 |
Thermocouple type |
R |
Weight (kg) |
270 |
Power supply required per phase |
380-415V 3 phase + N 40A, 220-240V 3 phase delta 62A, 380-415 3 phase no N 37A, 440-480V 3 phase + N 40A |
Please note
- Maximum continuous operating temperature is 100°C below maximum temperature
- Heat up rate is measured to 100°C below maximum, using an empty chamber
- Holding power is measured at continuous operating temperature
Content may be subject to modifications or corrections