HTMA 4/28
Max temp (°C) |
400 |
Volume (litres) |
28 |
[read more]
[read less]
Heat-up time (mins) |
60 |
Recovery time (mins) |
10 |
Dimensions: Internal H x W x D (mm) |
305 x 305 x 305 |
Dimensions: External H x W x D (mm) |
990 x 810 x 885 |
Shelves fitted / accepted |
2 / 2 |
Shelf loading each / total (kg) |
10 / 20 |
Max power (W) |
2000 |
Weight (kg) |
73 |
HTMA 4/95
Max temp (°C) |
400 |
Volume (litres) |
95 |
[read more]
[read less]
Heat-up time (mins) |
75 |
Recovery time (mins) |
16 |
Dimensions: Internal H x W x D (mm) |
455 x 455 x 455 |
Dimensions: External H x W x D (mm) |
1120 x 1015 x 1120 |
Shelves fitted / accepted |
3 / 4 |
Shelf loading each / total (kg) |
15 / 30 |
Max power (W) |
3000 |
Weight (kg) |
99 |
HTMA 4/220
Max temp (°C) |
400 |
Volume (litres) |
220 |
[read more]
[read less]
Heat-up time (mins) |
120 |
Recovery time (mins) |
20 |
Dimensions: Internal H x W x D (mm) |
610 x 610 x 610 |
Dimensions: External H x W x D (mm) |
1270 x 1165 x 1280 |
Shelves fitted / accepted |
3 / 4 |
Shelf loading each / total (kg) |
25 / 30 |
Max power (W) |
4000 |
Weight (kg) |
179 |
HTMA 4/500
Max temp (°C) |
400 |
Volume (litres) |
500 |
[read more]
[read less]
Heat-up time (mins) |
--- |
Recovery time (mins) |
--- |
Dimensions: Internal H x W x D (mm) |
800 x 800 x 800 |
Dimensions: External H x W x D (mm) |
1305 x 1115 x 1450 |
Shelves fitted / accepted |
3 / 5 |
Shelf loading each / total (kg) |
-- / -- |
Max power (W) |
7500 |
Weight (kg) |
--- |
HTMA 4/1000
Max temp (°C) |
400 |
Volume (litres) |
1000 |
[read more]
[read less]
Heat-up time (mins) |
--- |
Recovery time (mins) |
--- |
Dimensions: Internal H x W x D (mm) |
1000 x 1000 x 1000 |
Dimensions: External H x W x D (mm) |
1310 x 1530 x 1635 |
Shelves fitted / accepted |
3 / 5 |
Shelf loading each / total (kg) |
-- / -- |
Max power (W) |
12000 |
Weight (kg) |
--- |
HTMA 5/28
Max temp (°C) |
500 |
Volume (litres) |
28 |
[read more]
[read less]
Heat-up time (mins) |
60 |
Recovery time (mins) |
10 |
Dimensions: Internal H x W x D (mm) |
305 x 305 x 305 |
Dimensions: External H x W x D (mm) |
990 x 810 x 885 |
Shelves fitted / accepted |
2 / 2 |
Shelf loading each / total (kg) |
10 / 20 |
Max power (W) |
2000 |
Weight (kg) |
73 |
HTMA 5/95
Max temp (°C) |
500 |
Volume (litres) |
95 |
[read more]
[read less]
Heat-up time (mins) |
75 |
Recovery time (mins) |
16 |
Dimensions: Internal H x W x D (mm) |
455 x 455 x 455 |
Dimensions: External H x W x D (mm) |
1120 x 1015 x 1120 |
Shelves fitted / accepted |
3 / 4 |
Shelf loading each / total (kg) |
15 / 30 |
Max power (W) |
4500 |
Weight (kg) |
99 |
HTMA 5/220
Max temp (°C) |
500 |
Volume (litres) |
220 |
[read more]
[read less]
Heat-up time (mins) |
120 |
Recovery time (mins) |
20 |
Dimensions: Internal H x W x D (mm) |
610 x 610 x 610 |
Dimensions: External H x W x D (mm) |
1270 x 1165 x 1280 |
Shelves fitted / accepted |
3 / 4 |
Shelf loading each / total (kg) |
25 / 50 |
Max power (W) |
6000 |
Weight (kg) |
179 |
HTMA 5/500
Max temp (°C) |
500 |
Volume (litres) |
500 |
[read more]
[read less]
Heat-up time (mins) |
--- |
Recovery time (mins) |
--- |
Dimensions: Internal H x W x D (mm) |
800 x 800 x 800 |
Dimensions: External H x W x D (mm) |
1305 x 1115 x 1450 |
Shelves fitted / accepted |
3 / 5 |
Shelf loading each / total (kg) |
-- / -- |
Max power (W) |
9000 |
Weight (kg) |
--- |
HTMA 5/1000
Max temp (°C) |
500 |
Volume (litres) |
1000 |
[read more]
[read less]
Heat-up time (mins) |
--- |
Recovery time (mins) |
--- |
Dimensions: Internal H x W x D (mm) |
1000 x 1000 x 1000 |
Dimensions: External H x W x D (mm) |
1310 x 1530 x 1635 |
Shelves fitted / accepted |
3 / 5 |
Shelf loading each / total (kg) |
-- / -- |
Max power (W) |
15000 |
Weight (kg) |
--- |
HTMA 6/28
Max temp (°C) |
600 |
Volume (litres) |
28 |
[read more]
[read less]
Heat-up time (mins) |
60* |
Recovery time (mins) |
10* |
Dimensions: Internal H x W x D (mm) |
305 x 305 x 305 |
Dimensions: External H x W x D (mm) |
990 x 810 x 885 |
Shelves fitted / accepted |
2 / 2 |
Shelf loading each / total (kg) |
10 / 20 |
Max power (W) |
2000 |
Weight (kg) |
73 |
HTMA 6/95
Max temp (°C) |
600 |
Volume (litres) |
95 |
[read more]
[read less]
Heat-up time (mins) |
75* |
Recovery time (mins) |
16* |
Dimensions: Internal H x W x D (mm) |
455 x 455 x 455 |
Dimensions: External H x W x D (mm) |
1120 x 1015 x 1120 |
Shelves fitted / accepted |
3 / 4 |
Shelf loading (each) / total (kg) |
15 / 30 |
Max power (W) |
4500 |
Weight (kg) |
99 |
HTMA 6/220
Max temp (°C) |
600 |
Volume (litres) |
220 |
[read more]
[read less]
Heat-up time (mins) |
120* |
Recovery time (mins) |
20* |
Dimensions: Internal H x W x D (mm) |
610 x 610 x 610 |
Dimensions: External H x W x D (mm) |
1270 x 1165 x 1280 |
Shelves fitted / accepted |
3 / 4 |
Shelf loading each / total (kg) |
25 / 50 |
Max power (W) |
6000 |
Weight (kg) |
179 |
HTMA 6/500
Max temp (°C) |
600 |
Volume (litres) |
500 |
[read more]
[read less]
Heat-up time (mins) |
--- |
Recovery time (mins) |
--- |
Dimensions: Internal H x W x D (mm) |
800 x 800 x 800 |
Dimensions: External H x W x D (mm) |
1305 x 1115 x 1450 |
Shelves fitted / accepted |
3 / 5 |
Shelf loading each / total (kg) |
-- / -- |
Max power (W) |
12000 |
Weight (kg) |
--- |
HTMA 6/1000
Max temp (°C) |
600 |
Volume (litres) |
1000 |
[read more]
[read less]
Heat-up time (mins) |
--- |
Recovery time (mins) |
--- |
Dimensions: Internal H x W x D (mm) |
1000 x 1000 x 1000 |
Dimensions: External H x W x D (mm) |
1310 x 1530 x 1635 |
Shelves fitted / accepted |
3 / 5 |
Shelf loading each / total (kg) |
-- / -- |
Max power (W) |
15000 |
Weight (kg) |
--- |
HTMA 7/28
Max temp (°C) |
700 |
Volume (litres) |
28 |
[read more]
[read less]
Heat-up time (mins) |
90 |
Recovery time (mins) |
24 |
Dimensions: Internal H x W x D (mm) |
305 x 305 x 305 |
Dimensions: External H x W x D (mm) |
1140 x 910 x 910 |
Shelves fitted / accepted |
2 / 2 |
Shelf loading each / total (kg) |
8 / 16 |
Max power (W) |
3000 |
Weight (kg) |
85 |
HTMA 7/95
Max temp (°C) |
700 |
Volume (litres) |
95 |
[read more]
[read less]
Heat-up time (mins) |
95 |
Recovery time (mins) |
24 |
Dimensions: Internal H x W x D (mm) |
455 x 455 x 455 |
Dimensions: External H x W x D (mm) |
1280 x 1110 x 1160 |
Shelves fitted / accepted |
3 / 4 |
Shelf loading (each) / total (kg) |
10 / 30 |
Max power (W) |
6000 |
Weight (kg) |
115 |
HTMA 7/220
Max temp (°C) |
700 |
Volume (litres) |
220 |
[read more]
[read less]
Heat-up time (mins) |
120 |
Recovery time (mins) |
24 |
Dimensions: Internal H x W x D (mm) |
610 x 610 x 610 |
Dimensions: External H x W x D (mm) |
1295 x 1215 x 1280 |
Shelves fitted / accepted |
3 / 4 |
Shelf loading each / total (kg) |
15 / 45 |
Max power (W) |
10000 |
Weight (kg) |
195 |
Please note
- Uniformity is measured in an empty chamber with vents closed, after a stabilisation period
- * Nominal values based upon a representative sample of products
- Minimum operating temperature is approximately ambient +60°C
- Maximum power and heat up times based on a 240V supply
Content may be subject to modifications or corrections