Search

High Temperature Clean Room Oven - HTCR

HTCR4/28

Max temp (°C) 400
Min temp (°C) Ambient +60
Volume (litres) 28

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) 50
Recovery time (mins) 10
Dimensions:
Internal H x W x D (mm)
305 x 305 x 305
Dimensions:
External H x W x D (mm)
880 x 675 x 885
Shelves fitted / accepted 2 / 2
Shelf loading each / total (kg) 10 / 20
Configuration Bench-top
Max power (W) 2000

HTCR4/95

Max temp (°C) 400
Min temp (°C) Ambient +60
Volume (litres) 94

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) 90
Recovery time (mins) 10
Dimensions:
Internal H x W x D (mm)
455 x 455 x 455
Dimensions:
External H x W x D (mm)
1010 x 810 x 1120
Shelves fitted / accepted 3 / 4
Shelf loading each / total (kg) 15 / 30
Configuration Bench-top
Max power (W) 3000

HTCR4/220

Max temp (°C) 400
Min temp (°C) Ambient +60
Volume (litres) 227

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) 75
Recovery time (mins) 16
Dimensions:
Internal H x W x D (mm)
610 x 610 x 610
Dimensions:
External H x W x D (mm)
1160 x 1030 x 1280
Shelves fitted / accepted 3 / 4
Shelf loading each / total (kg) 10 / 50
Configuration Bench-top
Max power (W) 4000

HTCR4/500

Max temp (°C) 400
Min temp (°C) Ambient +60
Volume (litres) 510

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) --
Recovery time (mins) --
Dimensions:
Internal H x W x D (mm)
800 x 800 x 800
Dimensions:
External H x W x D (mm)
1305 x 1115 x 1450
Shelves fitted / accepted 3 / 5
Shelf loading each / total (kg) --
Configuration Floor-standing
Max power (W) 7500

HTCR4/1000

Max temp (°C) 400
Min temp (°C) Ambient +60
Volume (litres) 1000

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) --
Recovery time (mins) --
Dimensions:
Internal H x W x D (mm)
1000 x 1000 x 1000
Dimensions:
External H x W x D (mm)
1310 x 1530 x 1635
Shelves fitted / accepted 3 / 5
Shelf loading each / total (kg) --
Configuration Floor-standing
Max power (W) 12000

HTCR5/28

Max temp (°C) 500
Min temp (°C) Ambient +60
Volume (litres) 28

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) 75
Recovery time (mins) 16
Dimensions:
Internal H x W x D (mm)
305 x 305 x 305
Dimensions:
External H x W x D (mm)
880 x 675 x 885
Shelves fitted / accepted 2 / 2
Shelf loading each / total (kg) 10 / 20
Configuration Bench-top
Max power (W) 2000

HTCR5/95

Max temp (°C) 500
Min temp (°C) Ambient +60
Volume (litres) 94

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) 110
Recovery time (mins) 16
Dimensions:
Internal H x W x D (mm)
455 x 455 x 455
Dimensions:
External H x W x D (mm)
1010 x 810 x 1120
Shelves fitted / accepted 3 / 4
Shelf loading each / total (kg) 15 / 30
Configuration Bench-top
Max power (W) 4500

HTCR5/220

Max temp (°C) 500
Min temp (°C) Ambient +60
Volume (litres) 227

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) 105
Recovery time (mins) 16
Dimensions:
Internal H x W x D (mm)
610 x 610 x 610
Dimensions:
External H x W x D (mm)
1160 x 1030 x 1280
Shelves fitted / accepted 3 / 4
Shelf loading each / total (kg) 10 / 50
Configuration Bench-top
Max power (W) 6000

HTCR5/500

Max temp (°C) 500
Min temp (°C) Ambient +60
Volume (litres) 510

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) --
Recovery time (mins) --
Dimensions:
Internal H x W x D (mm)
800 x 800 x 800
Dimensions:
External H x W x D (mm)
1305 x 1155 x 1450
Shelves fitted / accepted 3 / 5
Shelf loading each / total (kg) 10 / 20
Configuration Floor-standing
Max power (W) 9000

HTCR5/1000

Max temp (°C) 500
Min temp (°C) Ambient +60
Volume (litres) 1000

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) --
Recovery time (mins) --
Dimensions:
Internal H x W x D (mm)
1000 x 1000 x 1000
Dimensions:
External H x W x D (mm)
1310 x 1530 x 1635
Shelves fitted / accepted 3 / 5
Shelf loading each / total (kg) 15 / 30
Configuration Floor-standing
Max power (W) 15000

HTCR6/28

Max temp (°C) 600
Min temp (°C) Ambient +60°C
Volume (litres) 28

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) 110
Recovery time (mins) 20
Dimensions:
Internal H x W x D (mm)
305 x 205 x 305
Dimensions:
External H x W x D (mm)
880 x 675 x 885
Shelves fitted / accepted 2 / 2
Shelf loading each / total (kg) 10 / 50
Configuration Bench-top
Max power (W) 2000

HTCR6/95

Max temp (°C) 600
Min temp (°C) Ambient +60
Volume (litres) 94

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) 110
Recovery time (mins) 20
Dimensions:
Internal H x W x D (mm)
455 x 455 x 455
Dimensions:
External H x W x D (mm)
1010 x 810 x 1120
Shelves fitted / accepted 3 / 4
Shelf loading each / total (kg) 10 / 20
Configuration Bench-top
Max power (W) 4500

HTCR6/220

Max temp (°C) 600
Min temp (°C) Ambient +60
Volume (litres) 227

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) 120
Recovery time (mins) 20
Dimensions:
Internal H x W x D (mm)
610 x 610 x 610
Dimensions:
External H x W x D (mm)
1160 x 1030 x 1280
Shelves fitted / accepted 3 / 4
Shelf loading each / total (kg) 15 / 30
Configuration Bench-top
Max power (W) 6000

HTCR6/500

Max temp (°C) 600
Min temp (°C) Ambient +60
Volume (litres) 510

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) --
Recovery time (mins) --
Dimensions:
Internal H x W x D (mm)
800 x 800 x 800
Dimensions:
External H x W x D (mm)
1305 x 1155 x 1450
Shelves fitted / accepted 3 / 5
Shelf loading each / total (kg) --
Configuration Floor-standing
Max power (W) 12000

HTCR6/1000

Max temp (°C) 600
Min temp (°C) Ambient +60
Volume (litres) 1000

[read more] [read less]

Temp stability (°C) ±0.5
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) --
Recovery time (mins) --
Dimensions:
Internal H x W x D (mm)
1000 x 1000 x 1000
Dimensions:
External H x W x D (mm)
1310 x 1530 x 1635
Shelves fitted / accepted 3 / 5
Shelf loading each / total (kg) --
Configuration Floor-standing
Max power (W) 22000

Please note
- Shelf loadings are based on evenly distributed weight
- Minimum operating temperature is approximately ambient +60°C
- The uniform volume is smaller than the overall chamber volume
- Maximum power and heat-up time based on a 240V supply

Content may be subject to modifications or corrections