GP220A
Max temp (°C) |
300 |
Volume (litres) |
220 |
[read more]
[read less]
Heat-up time (mins) |
75 |
Recovery time (mins) |
24 |
Temp stability (°C) |
±0.5 |
Temp uniformity (°C) |
±5.0 |
Dimensions: Internal H x W x D (mm) |
610 x 610 x 610 |
Dimensions: External H x W x D (mm) |
1240 x 862 x 850 |
Shelves fitted / accepted |
3 / 5 |
Shelf loading each / total (kg) |
15 / 45 |
Optional heavy duty reinforced base max. weight (kg) |
150 |
Optional heavy duty shelves max. quantity |
3 |
Optional heavy duty shelves max. weight / shelf (kg) |
50 |
Doors |
Single door |
Configuration |
Bench-top |
Air changes / hr (with optional exhaust fan) |
107 |
Max power (W) |
3000 |
GP330A
Max temp (°C) |
300 |
Volume (litres) |
330 |
[read more]
[read less]
Heat-up time (mins) |
80 |
Recovery time (mins) |
28 |
Temp stability (°C) |
±0.5 |
Temp uniformity (°C) |
±5.0 |
Dimensions: Internal H x W x D (mm) |
915 x 610 x 610 |
Dimensions: External H x W x D (mm) |
1545 x 862 x 850 |
Shelves fitted / accepted |
4 / 8 |
Shelf loading each / total (kg) |
15 / 60 |
Optional heavy duty reinforced base max. weight (kg) |
200 |
Optional heavy duty shelves max. quantity |
4 |
Optional heavy duty shelves max. weight / shelf (kg) |
50 |
Doors |
Single door |
Configuration |
Floor-standing |
Air changes / hr (with optional exhaust fan) |
76 |
Max power (W) |
4500 |
GP450A
Max temp (°C) |
300 |
Volume (litres) |
450 |
[read more]
[read less]
Heat-up time (mins) |
75 |
Recovery time (mins) |
30 |
Temp stability (°C) |
±0.5 |
Temp uniformity (°C) |
±5.0 |
Dimensions: Internal H x W x D (mm) |
1220 x 610 x 610 |
Dimensions: External H x W x D (mm) |
1850 x 862 x 850 |
Shelves fitted / accepted |
5 / 11 |
Shelf loading each / total (kg) |
15 / 75 |
Optional heavy duty reinforced base max. weight (kg) |
250 |
Optional heavy duty shelves max. quantity |
5 |
Optional heavy duty shelves max. weight / shelf (kg) |
50 |
Doors |
Single door |
Configuration |
Floor-standing |
Air changes / hr (with optional exhaust fan) |
59 |
Max power (W) |
6000 |
GP220B
Max temp (°C) |
300 |
Volume (litres) |
220 |
[read more]
[read less]
Heat-up time (mins) |
75 |
Recovery time (mins) |
24 |
Temp stability (°C) |
±0.5 |
Temp uniformity (°C) |
±5.0 |
Dimensions: Internal H x W x D (mm) |
610 x 610 x 610 |
Dimensions: External H x W x D (mm) |
910 x 1190 x 850 |
Shelves fitted / accepted |
3 / 5 |
Shelf loading each / total (kg) |
15 / 45 |
Optional heavy duty reinforced base max. weight (kg) |
150 |
Optional heavy duty shelves max. quantity |
3 |
Optional heavy duty shelves max. weight / shelf (kg) |
50 |
Doors |
Single door |
Configuration |
Bench-top |
Air changes / hr (with optional exhaust fan) |
107 |
Max power (W) |
3000 |
GP330B
Max temp (°C) |
300 |
Volume (litres) |
330 |
[read more]
[read less]
Heat-up time (mins) |
80 |
Recovery time (mins) |
30 |
Temp stability (°C) |
±0.5 |
Temp uniformity (°C) |
±5.0 |
Dimensions: Internal H x W x D (mm) |
610 x 915 x 610 |
Dimensions: External H x W x D (mm) |
910 x 1495 x 850 |
Shelves fitted / accepted |
3 / 5 |
Shelf loading each / total (kg) |
15 / 45 |
Optional heavy duty reinforced base max. weight (kg) |
225 |
Optional heavy duty shelves max. quantity |
3 |
Optional heavy duty shelves max. weight / shelf (kg) |
75 |
Doors |
Double door |
Configuration |
Bench-top |
Air changes / hr (with optional exhaust fan) |
76 |
Max power (W) |
4500 |
GP450B
Max temp (°C) |
300 |
Volume (litres) |
450 |
[read more]
[read less]
Heat-up time (mins) |
75 |
Recovery time (mins) |
35 |
Temp stability (°C) |
±0.5 |
Temp uniformity (°C) |
±5.0 |
Dimensions: Internal H x W x D (mm) |
610 x 1220 x 610 |
Dimensions: External H x W x D (mm) |
910 x 1800 x 850 |
Shelves fitted / accepted |
3 / 5 |
Shelf loading each / total (kg) |
20 / 60 |
Optional heavy duty reinforced base max. weight (kg) |
225 |
Optional heavy duty shelves max. quantity |
3 |
Optional heavy duty shelves max. weight / shelf (kg) |
75 |
Doors |
Double door |
Configuration |
Bench-top |
Air changes / hr (with optional exhaust fan) |
59 |
Max power (W) |
6000 |
Please note
- Uniformity is measured in an empty chamber with vents closed, after a stabilisation period
- Shelf loadings are based on evenly distributed weight
- Maximum power and heat up times based on a 240V supply
- The uniform volume is smaller than the total chamber volume
- Minimum operating temperature is approximately ambient +30°C
Content may be subject to modifications or corrections