Search

High Temperature Horizontal Tube Furnace - HTRH

HTRH __/40/100

Number of heated zones Single zone
Max outer diameter accessory tube (mm) 40
Heated length (mm) 100

[read more] [read less]

Max temp (°C) 1600
Dimensions:
External H x W x D (mm)
510 x 390 x 420
Furnace weight (kg) 45
Tube length for use in air (mm) 380
Tube length for use with modified atmosphere (mm) 915
Control module dimensions H x W x D (mm) 500 x 550 x 700
Control module weight (kg) 50
Uniform length ±5°C (mm) 50
Max power (W) 2200

HTRH __/40/250

Number of heated zones Single zone
Max outer diameter accessory tube (mm) 40
Heated length (mm) 250

[read more] [read less]

Max temp (°C) 1600, 1700, 1800
Dimensions:
External H x W x D (mm)
510 x 420 x 540
Furnace weight (kg) 45
Tube length for use in air (mm) 530
Tube length for use with modified atmosphere (mm) 1065
Control module dimensions H x W x D (mm) 500 x 550 x 700
Control module weight (kg) 50
Uniform length ±5°C (mm) 125
Max power (W) 3600

HTRH __/40/500

Number of heated zones Single zone
Max outer diameter accessory tube (mm) 40
Heated length (mm) 500

[read more] [read less]

Max temp (°C) 1600, 1700, 1800
Dimensions:
External H x W x D (mm)
510 x 420 x 790
Furnace weight (kg) 60
Tube length for use in air (mm) 780
Tube length for use with modified atmosphere (mm) 1275
Control module dimensions H x W x D (mm) 850 x 550 x 700
Control module weight (kg) 90
Uniform length ±5°C (mm) 250
Max power (W) 8000

HTRH __/70/150

Number of heated zones Single zone
Max outer diameter accessory tube (mm) 70
Heated length (mm) 150

[read more] [read less]

Max temp (°C) 1600, 1700
Dimensions:
External H x W x D (mm)
620 x 520 x 450
Furnace weight (kg) 65
Tube length for use in air (mm) 440
Tube length for use with modified atmosphere (mm) 975
Control module dimensions H x W x D (mm) 500 x 550 x 700
Control module weight (kg) 60
Uniform length ±5°C (mm) 75
Max power (W) 4500

HTRH __/70/300

Number of heated zones Single zone
Max outer diameter accessory tube (mm) 70
Heated length (mm) 300

[read more] [read less]

Max temp (°C) 1600, 1700, 1800
Dimensions:
External H x W x D (mm)
620 x 520 x 590
Furnace weight (kg) 65
Tube length for use in air (mm) 580
Tube length for use with modified atmosphere (mm) 1115
Control module dimensions H x W x D (mm) 850 x 550 x 700
Control module weight (kg) 60
Uniform length ±5°C (mm) 150
Max power (W) 6400

HTRH __/70/600

Number of heated zones Single zone
Max outer diameter accessory tube (mm) 70
Heated length (mm) 600

[read more] [read less]

Max temp (°C) 1600, 1700, 1800
Dimensions:
External H x W x D (mm)
620 x 520 x 890
Furnace weight (kg) 90
Tube length for use in air (mm) 880
Tube length for use with modified atmosphere (mm) 1415
Control module dimensions H x W x D (mm) 850 x 550 x 700
Control module weight (kg) 90
Uniform length ±5°C (mm) 300
Max power (W) 8000

HTRH __/100/150

Number of heated zones Single zone
Max outer diameter accessory tube (mm) 100
Heated length (mm) 150

[read more] [read less]

Max temp (°C) 1600
Dimensions:
External H x W x D (mm)
620 x 520 x 450
Furnace weight (kg) 75
Tube length for use in air (mm) 440
Tube length for use with modified atmosphere (mm) 975
Control module dimensions H x W x D (mm) 500 x 550 x 700
Control module weight (kg) 60
Uniform length ±5°C (mm) 75
Max power (W) 4800

HTRH __/100/300

Number of heated zones Single zone
Max outer diameter accessory tube (mm) 100
Heated length (mm) 300

[read more] [read less]

Max temp (°C) 1600, 1700, 1800
Dimensions:
External H x W x D (mm)
620 x 520 x 590
Furnace weight (kg) 90
Tube length for use in air (mm) 580
Tube length for use with modified atmosphere (mm) 1115
Control module dimensions H x W x D (mm) 850 x 550 x 700
Control module weight (kg) 90
Uniform length ±5°C (mm) 150
Max power (W) 7500

HTRH __/100/600

Number of heated zones Single zone
Max outer diameter accessory tube (mm) 100
Heated length (mm) 600

[read more] [read less]

Max temp (°C) 1600, 1700, 1800
Dimensions:
External H x W x D (mm)
620 x 520 x 890
Furnace weight (kg) 140
Tube length for use in air (mm) 880
Tube length for use with modified atmosphere (mm) 1415
Control module dimensions H x W x D (mm) 850 x 550 x 700
Control module weight (kg) 90
Uniform length ±5°C (mm) 300
Max power (W) 10900

HTRH __/150/600

Number of heated zones Single zone
Max outer diameter accessory tube (mm) 150
Heated length (mm) 600

[read more] [read less]

Max temp (°C) 1600, 1700, 1800
Dimensions:
External H x W x D (mm)
670 x 570 x 890
Furnace weight (kg) 140
Tube length for use in air (mm) 880
Tube length for use with modified atmosphere (mm) -
Control module dimensions H x W x D (mm) 850 x 550 x 700
Control module weight (kg) 90
Uniform length ±5°C (mm) -
Max power (W) 12000

HTRH __/200/600

Number of heated zones Single zone
Max outer diameter accessory tube (mm) 200
Heated length (mm) 600

[read more] [read less]

Max temp (°C) 1600, 1700, 1800
Dimensions:
External H x W x D (mm)
720 x 620 x 890
Furnace weight (kg) 180
Tube length for use in air (mm) 880
Tube length for use with modified atmosphere (mm) -
Control module dimensions H x W x D (mm) 850 x 550 x 700
Control module weight (kg) 90
Uniform length ±5°C (mm) -
Max power (W) 12000

HTRH-3 __/70/600

Number of heated zones Three zone
Max outer diameter accessory tube (mm) 70
Heated length (mm) 600

[read more] [read less]

Max temp (°C) 1600, 1700, 1800
Dimensions:
External H x W x D (mm)
620 x 890 x 520
Furnace weight (kg) 120
Tube length for use in air (mm) 880
Tube length for use with modified atmosphere (mm) 1415
Control module dimensions H x W x D (mm) 850 x 550 x 700
Control module weight (kg) 180
Uniform length ±5°C (mm) 350
Max power (W) 8000

HTRH-3 __/100/600

Number of heated zones Three zone
Max outer diameter accessory tube (mm) 100
Heated length (mm) 600

[read more] [read less]

Max temp (°C) 1600, 1700, 1800
Dimensions:
External H x W x D (mm)
620 x 890 x 520
Furnace weight (kg) 120
Tube length for use in air (mm) 880
Tube length for use with modified atmosphere (mm) 1415
Control module dimensions H x W x D (mm) 850 x 550 x 700
Control module weight (kg) 180
Uniform length ±5°C (mm) 350
Max power (W) 10900

HTRH-3 __/100/900

Number of heated zones Three zone
Max outer diameter accessory tube (mm) 100
Heated length (mm) 900

[read more] [read less]

Max temp (°C) 1600, 1700, 1800
Dimensions:
External H x W x D (mm)
680 x 1190 x 650
Furnace weight (kg) 250
Tube length for use in air (mm) 1180
Tube length for use with modified atmosphere (mm) 1715
Control module dimensions H x W x D (mm) 1100 x 1200 x 700
Control module weight (kg) 230
Uniform length ±5°C (mm) -
Max power (W) 20000

HTRH-3 __/150/600

Number of heated zones Three zone
Max outer diameter accessory tube (mm) 150
Heated length (mm) 600

[read more] [read less]

Max temp (°C) 1600, 1700, 1800
Dimensions:
External H x W x D (mm)
670 x 890 x 570
Furnace weight (kg) 180
Tube length for use in air (mm) 880
Tube length for use with modified atmosphere (mm) -
Control module dimensions H x W x D (mm) 850 x 550 x 700
Control module weight (kg) 180
Uniform length ±5°C (mm) 350
Max power (W) 12000

HTRH-3 __/150/900

Number of heated zones Three zone
Max outer diameter accessory tube (mm) 150
Heated length (mm) 900

[read more] [read less]

Max temp (°C) 1600, 1700, 1800
Dimensions:
External H x W x D (mm)
680 x 1190 x 650
Furnace weight (kg) 250
Tube length for use in air (mm) 1180
Tube length for use with modified atmosphere (mm) -
Control module dimensions H x W x D (mm) 1100 x 1200 x 700
Control module weight (kg) 230
Uniform length ±5°C (mm) -
Max power (W) 20000

Please note
- Heat up rate when using a ceramic work tube must be limited to 5 °C/min
- The power supply is based on 200 – 240 V for 1 phase and 380 – 415 V for 3 phase power
- Minimum uniform length in horizontal furnace with insulation plugs fitted at 100 °C below max. temperature
- Maximum continuous operating temperature is 100°C below maximum temperature
- Further to the depth of the control module 150 mm for the power plugs and other plugs needs to be added