HTRH __/40/100
Number of heated zones |
Single zone |
Max outer diameter accessory tube (mm) |
40 |
Heated length (mm) |
100 |
[read more]
[read less]
Max temp (°C) |
1600 |
Dimensions: External H x W x D (mm) |
510 x 390 x 420 |
Furnace weight (kg) |
45 |
Tube length for use in air (mm) |
380 |
Tube length for use with modified atmosphere (mm) |
915 |
Control module dimensions H x W x D (mm) |
500 x 550 x 700 |
Control module weight (kg) |
50 |
Uniform length ±5°C (mm) |
50 |
Max power (W) |
2200 |
HTRH __/40/250
Number of heated zones |
Single zone |
Max outer diameter accessory tube (mm) |
40 |
Heated length (mm) |
250 |
[read more]
[read less]
Max temp (°C) |
1600, 1700, 1800 |
Dimensions: External H x W x D (mm) |
510 x 420 x 540 |
Furnace weight (kg) |
45 |
Tube length for use in air (mm) |
530 |
Tube length for use with modified atmosphere (mm) |
1065 |
Control module dimensions H x W x D (mm) |
500 x 550 x 700 |
Control module weight (kg) |
50 |
Uniform length ±5°C (mm) |
125 |
Max power (W) |
3600 |
HTRH __/40/500
Number of heated zones |
Single zone |
Max outer diameter accessory tube (mm) |
40 |
Heated length (mm) |
500 |
[read more]
[read less]
Max temp (°C) |
1600, 1700, 1800 |
Dimensions: External H x W x D (mm) |
510 x 420 x 790 |
Furnace weight (kg) |
60 |
Tube length for use in air (mm) |
780 |
Tube length for use with modified atmosphere (mm) |
1275 |
Control module dimensions H x W x D (mm) |
850 x 550 x 700 |
Control module weight (kg) |
90 |
Uniform length ±5°C (mm) |
250 |
Max power (W) |
8000 |
HTRH __/70/150
Number of heated zones |
Single zone |
Max outer diameter accessory tube (mm) |
70 |
Heated length (mm) |
150 |
[read more]
[read less]
Max temp (°C) |
1600, 1700 |
Dimensions: External H x W x D (mm) |
620 x 520 x 450 |
Furnace weight (kg) |
65 |
Tube length for use in air (mm) |
440 |
Tube length for use with modified atmosphere (mm) |
975 |
Control module dimensions H x W x D (mm) |
500 x 550 x 700 |
Control module weight (kg) |
60 |
Uniform length ±5°C (mm) |
75 |
Max power (W) |
4500 |
HTRH __/70/300
Number of heated zones |
Single zone |
Max outer diameter accessory tube (mm) |
70 |
Heated length (mm) |
300 |
[read more]
[read less]
Max temp (°C) |
1600, 1700, 1800 |
Dimensions: External H x W x D (mm) |
620 x 520 x 590 |
Furnace weight (kg) |
65 |
Tube length for use in air (mm) |
580 |
Tube length for use with modified atmosphere (mm) |
1115 |
Control module dimensions H x W x D (mm) |
850 x 550 x 700 |
Control module weight (kg) |
60 |
Uniform length ±5°C (mm) |
150 |
Max power (W) |
6400 |
HTRH __/70/600
Number of heated zones |
Single zone |
Max outer diameter accessory tube (mm) |
70 |
Heated length (mm) |
600 |
[read more]
[read less]
Max temp (°C) |
1600, 1700, 1800 |
Dimensions: External H x W x D (mm) |
620 x 520 x 890 |
Furnace weight (kg) |
90 |
Tube length for use in air (mm) |
880 |
Tube length for use with modified atmosphere (mm) |
1415 |
Control module dimensions H x W x D (mm) |
850 x 550 x 700 |
Control module weight (kg) |
90 |
Uniform length ±5°C (mm) |
300 |
Max power (W) |
8000 |
HTRH __/100/150
Number of heated zones |
Single zone |
Max outer diameter accessory tube (mm) |
100 |
Heated length (mm) |
150 |
[read more]
[read less]
Max temp (°C) |
1600 |
Dimensions: External H x W x D (mm) |
620 x 520 x 450 |
Furnace weight (kg) |
75 |
Tube length for use in air (mm) |
440 |
Tube length for use with modified atmosphere (mm) |
975 |
Control module dimensions H x W x D (mm) |
500 x 550 x 700 |
Control module weight (kg) |
60 |
Uniform length ±5°C (mm) |
75 |
Max power (W) |
4800 |
HTRH __/100/300
Number of heated zones |
Single zone |
Max outer diameter accessory tube (mm) |
100 |
Heated length (mm) |
300 |
[read more]
[read less]
Max temp (°C) |
1600, 1700, 1800 |
Dimensions: External H x W x D (mm) |
620 x 520 x 590 |
Furnace weight (kg) |
90 |
Tube length for use in air (mm) |
580 |
Tube length for use with modified atmosphere (mm) |
1115 |
Control module dimensions H x W x D (mm) |
850 x 550 x 700 |
Control module weight (kg) |
90 |
Uniform length ±5°C (mm) |
150 |
Max power (W) |
7500 |
HTRH __/100/600
Number of heated zones |
Single zone |
Max outer diameter accessory tube (mm) |
100 |
Heated length (mm) |
600 |
[read more]
[read less]
Max temp (°C) |
1600, 1700, 1800 |
Dimensions: External H x W x D (mm) |
620 x 520 x 890 |
Furnace weight (kg) |
140 |
Tube length for use in air (mm) |
880 |
Tube length for use with modified atmosphere (mm) |
1415 |
Control module dimensions H x W x D (mm) |
850 x 550 x 700 |
Control module weight (kg) |
90 |
Uniform length ±5°C (mm) |
300 |
Max power (W) |
10900 |
HTRH __/150/600
Number of heated zones |
Single zone |
Max outer diameter accessory tube (mm) |
150 |
Heated length (mm) |
600 |
[read more]
[read less]
Max temp (°C) |
1600, 1700, 1800 |
Dimensions: External H x W x D (mm) |
670 x 570 x 890 |
Furnace weight (kg) |
140 |
Tube length for use in air (mm) |
880 |
Tube length for use with modified atmosphere (mm) |
- |
Control module dimensions H x W x D (mm) |
850 x 550 x 700 |
Control module weight (kg) |
90 |
Uniform length ±5°C (mm) |
- |
Max power (W) |
12000 |
HTRH __/200/600
Number of heated zones |
Single zone |
Max outer diameter accessory tube (mm) |
200 |
Heated length (mm) |
600 |
[read more]
[read less]
Max temp (°C) |
1600, 1700, 1800 |
Dimensions: External H x W x D (mm) |
720 x 620 x 890 |
Furnace weight (kg) |
180 |
Tube length for use in air (mm) |
880 |
Tube length for use with modified atmosphere (mm) |
- |
Control module dimensions H x W x D (mm) |
850 x 550 x 700 |
Control module weight (kg) |
90 |
Uniform length ±5°C (mm) |
- |
Max power (W) |
12000 |
HTRH-3 __/70/600
Number of heated zones |
Three zone |
Max outer diameter accessory tube (mm) |
70 |
Heated length (mm) |
600 |
[read more]
[read less]
Max temp (°C) |
1600, 1700, 1800 |
Dimensions: External H x W x D (mm) |
620 x 890 x 520 |
Furnace weight (kg) |
120 |
Tube length for use in air (mm) |
880 |
Tube length for use with modified atmosphere (mm) |
1415 |
Control module dimensions H x W x D (mm) |
850 x 550 x 700 |
Control module weight (kg) |
180 |
Uniform length ±5°C (mm) |
350 |
Max power (W) |
8000 |
HTRH-3 __/100/600
Number of heated zones |
Three zone |
Max outer diameter accessory tube (mm) |
100 |
Heated length (mm) |
600 |
[read more]
[read less]
Max temp (°C) |
1600, 1700, 1800 |
Dimensions: External H x W x D (mm) |
620 x 890 x 520 |
Furnace weight (kg) |
120 |
Tube length for use in air (mm) |
880 |
Tube length for use with modified atmosphere (mm) |
1415 |
Control module dimensions H x W x D (mm) |
850 x 550 x 700 |
Control module weight (kg) |
180 |
Uniform length ±5°C (mm) |
350 |
Max power (W) |
10900 |
HTRH-3 __/100/900
Number of heated zones |
Three zone |
Max outer diameter accessory tube (mm) |
100 |
Heated length (mm) |
900 |
[read more]
[read less]
Max temp (°C) |
1600, 1700, 1800 |
Dimensions: External H x W x D (mm) |
680 x 1190 x 650 |
Furnace weight (kg) |
250 |
Tube length for use in air (mm) |
1180 |
Tube length for use with modified atmosphere (mm) |
1715 |
Control module dimensions H x W x D (mm) |
1100 x 1200 x 700 |
Control module weight (kg) |
230 |
Uniform length ±5°C (mm) |
- |
Max power (W) |
20000 |
HTRH-3 __/150/600
Number of heated zones |
Three zone |
Max outer diameter accessory tube (mm) |
150 |
Heated length (mm) |
600 |
[read more]
[read less]
Max temp (°C) |
1600, 1700, 1800 |
Dimensions: External H x W x D (mm) |
670 x 890 x 570 |
Furnace weight (kg) |
180 |
Tube length for use in air (mm) |
880 |
Tube length for use with modified atmosphere (mm) |
- |
Control module dimensions H x W x D (mm) |
850 x 550 x 700 |
Control module weight (kg) |
180 |
Uniform length ±5°C (mm) |
350 |
Max power (W) |
12000 |
HTRH-3 __/150/900
Number of heated zones |
Three zone |
Max outer diameter accessory tube (mm) |
150 |
Heated length (mm) |
900 |
[read more]
[read less]
Max temp (°C) |
1600, 1700, 1800 |
Dimensions: External H x W x D (mm) |
680 x 1190 x 650 |
Furnace weight (kg) |
250 |
Tube length for use in air (mm) |
1180 |
Tube length for use with modified atmosphere (mm) |
- |
Control module dimensions H x W x D (mm) |
1100 x 1200 x 700 |
Control module weight (kg) |
230 |
Uniform length ±5°C (mm) |
- |
Max power (W) |
20000 |
Please note
- Heat up rate when using a ceramic work tube must be limited to 5 °C/min
- The power supply is based on 200 – 240 V for 1 phase and 380 – 415 V for 3 phase power
- Minimum uniform length in horizontal furnace with insulation plugs fitted at 100 °C below max. temperature
- Maximum continuous operating temperature is 100°C below maximum temperature
- Further to the depth of the control module 150 mm for the power plugs and other plugs needs to be added
Content may be subject to modifications or corrections